Precision air conditioning · server rooms
Precision air conditioning for server rooms
Precision air conditioning is a cooling system for server rooms and technical rooms that keeps temperature and humidity stable all year round, usually 18-27 °C at the server air inlet as recommended by ASHRAE. ColdBack selects, installs and services precision air conditioning and cooling cabinets with redundancy and alarms throughout Masovia (Mazowieckie Province). We work with equipment from STULZ, Emerson and Mitsubishi, among others.
- 18-27 °Cinlet temperature (ASHRAE)
- N+1equipment redundancy
- 365 daysyear-round operation
- F-gascompany certificate

Cooling that cannot stop
A server room generates heat around the clock, in winter too. A standard air conditioner is not built for this, so we select units for continuous operation and always with spare capacity.
Cooling capacity sizing
Almost all the energy drawn by IT equipment turns into heat. We calculate capacity from power draw, UPS and a margin for expansion.
Precision air conditioning cabinets
Floor-standing units with temperature and humidity control for medium and large server rooms, including STULZ, Emerson and Mitsubishi.
Air conditioning for small server rooms
Units designed to run all year round, including in sub-zero outdoor temperatures.
N+1 redundancy
Two or more units with automatic changeover and duty rotation. If one fails, cooling does not stop.
Alarms and monitoring
Temperature and humidity sensors, with an alarm when limits are exceeded or a unit fails.
Service and contract
Maintenance inspections on fixed dates and a service contract with 24/7 on-call service.
Who we work for
- Company server roomsRooms with rack cabinets in offices and plants.
- Telecoms roomsNetwork nodes and rooms with active equipment.
- Switch rooms and UPSRooms with UPS batteries that need a stable temperature.
- LaboratoriesRooms with temperature and humidity requirements.
- Archives and storeroomsA stable climate for documents and sensitive materials.
- Offices and schoolsSmall server rooms in buildings with no space for large units.
How it works
01Room auditIT power draw, room size, space for outdoor units.
02Selection and quoteCapacity, redundancy, controls and alarms. Quote within 48 hours.
03InstallationInstallation in stages, with no interruption to server room operation.
04CommissioningTest of unit changeover and alarms, commissioning report.
05ServiceMaintenance inspections and a service contract with 24/7 on-call service.
Service area
We install and service precision air conditioning throughout Masovia (Mazowieckie Province) from our base in Majdan near Warsaw. Clients with a service contract get 24/7 on-call service.
Frequently asked questions
How is precision air conditioning different from standard air conditioning?
Precision air conditioning runs around the clock all year, including in sub-zero outdoor temperatures, holds temperature to within a few degrees and controls humidity. It is also designed for heat given off by equipment rather than by people and sunlight. A standard comfort air conditioner is not built for continuous operation and wears out faster.
What temperature should a server room be?
ASHRAE, the organisation that sets standards for server rooms, recommends a server inlet air temperature of 18 to 27 °C. We keep humidity at a level that avoids condensation and static charge. Stable temperature matters more than low temperature.
How do you size air conditioning for a server room?
The starting point is the power draw of the IT equipment, because almost all of that energy turns into heat. On top of that come UPS losses, lighting, people and heat from the surroundings. We add a margin for expansion and select units so that one can take over from another.
What is N+1 redundancy?
It is a setup with one more unit than is needed to cover the full load. When one unit fails or is being serviced, the others keep cooling the server room. The controller switches units automatically and rotates their duty so they wear evenly.
Can you respond to a breakdown at night?
Clients with a service contract get 24/7 on-call service, including weekends and public holidays. For server rooms we always recommend a contract, because the time it takes servers to start shutting down after cooling stops is usually short.
Which equipment do you work with?
We install and service precision air conditioning from STULZ, Emerson and Mitsubishi, among others. We select units to match the load, the size of the server room and the redundancy required, and we also service systems installed by other companies.